Top
Airstream Services Commercial HVAC

Commercial HVAC Murfreesboro, TN

Proudly Serving Businesses Throughout Middle Tennessee

Airstream Services provides the latest in commercial HVAC systems. Our leading brand is the Fujitsu Airstage V-II(Heat Pump) and Airstage VR-II(Heat Recovery) systems. These systems are variable refrigerant flow(VRF) systems. We also provide Mitsubishi, Samsung, Diakin, Gree and LG depending on your needs and what type of system you are looking to help heat and cool your place of business. 

Top Commercial HVAC Systems and Services

Variable refrigerant flow (VRF) is an HVAC technology invented in Japan by Daikin company in 1982. Like ductless mini splits VRFs use refrigerant as the cooling and heating medium. This refrigerant is conditioned by a single outdoor condensing unit, and is circulated within the building to multiple fan-coil units (FCUs).

Energy-Efficient VRF Technology for Businesses

VRFs are typically installed with an air conditioner inverter which adds a DC inverter to the compressor in order to support variable motor speed and thus variable refrigerant flow rather than simply perform on/off operation. By operating at varying speeds, VRF units work only at the needed rate allowing for substantial energy savings at partial-load conditions. Heat recovery VRF technology allows individual indoor units to heat or cool as required, while the compressor load benefits from the internal heat recovery. Energy savings of up to 55% are predicted over comparable unitary equipment. This also results in greater control of the building's interior temperature by the building's occupants.

Advanced Heat Recovery Systems for Optimal Comfort

VRFs come in two system formats, two pipe and three pipe systems. In a heat pump 2 pipe system all of the zones must either be all in cooling or all in heating. Heat Recovery (HR) systems have the ability to simultaneously heat certain zones while cooling others; this is usually done through a three pipe design, with the exception of Mitsubishi which is able to do this with a 2 pipe system using a BC controller to the individual indoor evaporator zones. In this case the heat extracted from zones requiring cooling is put to use in the zones requiring heating. This is made possible because the heating unit is functioning as a condenser, providing sub-cooled liquid back into the line that is being used for cooling. While the heat recovery system has a greater initial cost, it allows for better zoned thermal control of a building and overall greater efficiencies.

Commercial HVAC Systems

Airstream Services provides the latest in commercial HVAC systems. Our leading brand is the Fujitsu Airstage V-II(Heat Pump) and Airstage VR-II(Heat Recovery) systems. These systems are variable refrigerant flow(VRF) systems. We also provide Mitsubishi, Samsung, Diakin, Gree and LG depending on your needs and what type of system you are looking to help heat and cool your place of business. 

Variable Refrigerant Flow

Variable refrigerant flow (VRF) is an HVAC technology invented in Japan by Daikin company in 1982. Like ductless mini splits VRFs use refrigerant as the cooling and heating medium. This refrigerant is conditioned by a single outdoor condensing unit, and is circulated within the building to multiple fan-coil units (FCUs).

VRFs are typically installed with an air conditioner inverter which adds a DC inverter to the compressor in order to support variable motor speed and thus variable refrigerant flow rather than simply perform on/off operation. By operating at varying speeds, VRF units work only at the needed rate allowing for substantial energy savings at partial-load conditions. Heat recovery VRF technology allows individual indoor units to heat or cool as required, while the compressor load benefits from the internal heat recovery. Energy savings of up to 55% are predicted over comparable unitary equipment. This also results in greater control of the building's interior temperature by the building's occupants.

VRFs come in two system formats, two pipe and three pipe systems. In a heat pump 2 pipe system all of the zones must either be all in cooling or all in heating. Heat Recovery (HR) systems have the ability to simultaneously heat certain zones while cooling others; this is usually done through a three pipe design, with the exception of Mitsubishi which is able to do this with a 2 pipe system using a BC controller to the individual indoor evaporator zones. In this case the heat extracted from zones requiring cooling is put to use in the zones requiring heating. This is made possible because the heating unit is functioning as a condenser, providing sub-cooled liquid back into the line that is being used for cooling. While the heat recovery system has a greater initial cost, it allows for better zoned thermal control of a building and overall greater efficiencies.

Hear Stories From Those We've Helped! Our Reviews

  • “Airstream knock it out of the park! They installed an EV charger for me and it looks fantastic! I deal with vendors on a weekly bases for both my home and businesses. Customer service, professionalism or just a call back no longer exist.” - Mike D.
  • “Airstream services did an excellent job in resolving my HVAC issues. Technicians are very well qualified and affordable prices for service. Technician Matt was super knowledgeable to identify the issue and also patient to explain to me all the details that” - Sandeep B.
  • “Airstream replaced an older central unit and installed an EV charger at our home. Both jobs were performed as scheduled and for the quoted prices. Pricing was fair and all of their guys showed up on time. Their work was tidy, and the install guys were all ” - Taylor S.
  • “I had an outlet arc and burn, taking out all the outlets in half my kitchen. I called Airstream and they sent someone out within a few hours.” - Mary N.
  • “We used Airstream Services for several years when our heat pump needed to be replaced. We had them do the replacement with a high efficiency heat pump. We were happy with the price and the professional service.” - Jeff K.
  • “Connor installed our car charger in the garage and was very efficient and friendly. He was in and out in less than an hour. Also, speaking with Julia on the phone from their office was always a pleasant and friendly exchange.” - Jonathan M.
  • “We had gemstone lights installed. Can’t be happier we went with them even though we heard cheaper options from other vendors.” - Sri T.
  • “Our A/C went out at our Dental Office last week which happened to be the hottest week so far this year. We received a quote from another company and it was going to be 60 weeks for a new unit. I then reached out to Airstream (someone else referred them to ” - Allison B.
Middle Tennessee's Premier HVAC & Electrical Service Provider Contact Us Request Your Free Estimate